Cell Type | Ni-Mh | Voltage | 12V |
---|---|---|---|
Weight | 2300g | Size | 255*103*77mm |
Capacity | 10000mAh | Charger | GKL22 |
Color | Red | Condition | New |
High Light | GEB171 Total Station Batteries,10000mAh Total Station Batteries,GEB171 Lithium Ion Rechargeable Battery |
Leica Battery External Rechargeable Battery GEB171 12V 10000mAh for Leica Total Station TPS1000,TCA1800,TC2005
Model: GEB171
Specifications:
Voltage | 12V |
Weight | 2300g |
Size | 255*103*77mm |
Type | Ni-Mh |
Capacity | 10000mAh |
Package | Individual Box Package |
Warranty | 1 Year |
Charger | GKL22 |
Used For | Leica Total Stations |
Used For Instruments:
TPS100 TCA1800 TC2003 TPS100 TCA1800 TC2005 Series Total Station
Storage
Leica Geosystems batteries can be stored at –40 °C to +55 °C (–40 °F to +131 °F). Do not store batteries inside the surveying instrument. After storage, charge the battery fully before use. NiCd NiCd batteries can be stored for an unlimited period in any state of charge. NiMH NiMH batteries must always be stored fully charged and recharged after 180 days at the latest. High temperatures and high atmospheric humidity accelerate self-discharging. We recommend storage in the range from 0 °C to +20 °C (+32 °F to +68 °F) in a dry environment. If NiMH batteries are stored in the discharged state for an extended period irreversible damage can be caused. Li-Ion Li-Ion batteries start to deteriorate from manufacture. To reduce the aging effect, store the battery in a cool place at 10%–50% state-of-charge. Li-Ion batteries do not require regular charging while in storage.
Memory effect
The «Memory Effect» occurs if the same charging and discharging (partial discharge) conditions are continuously applied to a battery. The battery then no longer provides the full capacity. The operating time per battery charge reduces. If the capacity of the battery drops noticeably, it is recommended to subject the battery to the refresh function 2 to 3 times (see Section 2.9). The memory effect occurs particularly with NiCd batteries. With NiMH batteries the memory effect is not so pronounced. Li-Ion batteries are not influenced by the memory effect.
Battery refresh function
If the capacity of a NiCd or NiMH battery drops noticeably, the battery can be refreshed using two to three full charge and discharge cycles. The GKL221 Charging Station has a discharging and charging function for refreshing batteries. Since GKL112 and GKL211 do not have a discharge function the batteries are to be discharged in the instrument (i.e. operate until the instrument switches off).